FC Series Fan and Heater Control 
        
       Control ventilation and heating with one easy-to-use controller
The Fan and Heater Control (FC-1T-1VAC-1F) automatically controls the temperature in a room by adjusting the speed of variable speed fans and controlling a heater interlock.
How it works
- When the temperature is at the temperature set point, the FC-1T-1VAC-1F operates the fans at the idle speed setting and the heater is off.
 - When the temperature exceeds the set point, it increases the speed of the fans.
 - When the temperature drops below the set point, it shuts off the fans (in shut-off mode) or operates the fans at idle speed (idle mode) and switches on the heater or heat lamps.
 
Features
- One variable stage
 - One heater interlock output
 - Automatic shut-off and idle modes
 - Adjustable off set-back for shut-off mode (0 to 16°F)
 - Adjustable idle speed for idle mode (0 to 99%)
 - Adjustable temperature set point, range: 32 to 99°F (0 to 37°C)
 - Adjustable temperature differential (1 to 20°F)
 - Three-second full-power-turn-on to minimize fan ice-up
 - LED display
 - Fahrenheit and Celsius display
 - Error code display for troubleshooting
 - Overload protection fuse
 - Six-foot temperature sensor, extendable to 500 feet
 - NEMA 4X enclosure (corrosion resistant, water resistant, and fire retardant)
 - CSA approval
 - Two-year limited warranty
 
Electrical ratings
Input
- 120/230 VAC, 50/60 Hz
 
Variable stage
- 10 A at 120/230 VAC, general-purpose (resistive)
 - 7 FLA at 120/230 VAC, PSC motor
 - 1/2 HP at 120 VAC, 1 HP at 230 VAC, PSC motor
 
Variable fuse
- 15 A, 250 VAC ABC-type ceramic
 
Relay
- 10 A at 120/230 VAC, general-purpose (resistive)
 - 1/3 HP at 120 VAC, 1/2 HP at 230 VAC
 - 360 W tungsten at 120 VAC